              在低溫季節回收制冷劑注意事項

               

               

              購買防爆空調流程

              • 1、聯系在線客服或撥打0577-62884866,62994866咨詢產品信息
              • 2、議定型號,數量,付款方式(匯款、代收)、運輸及售后服務
              • 3、傳真方式簽訂購銷合同
              • 4、雙方按合同約定履行責任和義務
               

              在低溫季節回收制冷劑注意事項:
                  防爆單冷型空調器不設置電磁四通換向閥,壓縮機的運轉與停止主要由溫度控制器控制,在低溫季節里溫度控制器開關觸點處在常開狀態,所以壓縮機無法運轉。這時必須用熱毛巾對溫度控制器的感溫頭(或感溫管)加熱,迫使其觸點閉合。開機后進行制冷劑回收操作(或改變接線強制運轉進行)。
                  防爆熱泵型空調器在低溫季節回收制冷劑時,若帶有直通功能(如防爆三菱空調機),可將運轉模式定于CONSTANT制冷狀態,這樣壓縮機不受控制器控制而直接進行制冷,制冷時可操作室外機進行制冷劑回收。
                  防爆熱泵型空調器在低溫季節回收制冷劑時,若不帶直通功能,應采用強制控制開關或人為強制控制解決。防爆熱泵型空調器的制冷與制熱運轉模式轉換是靠電磁四通換向閥的換向完成的。電磁四通換向閥失電時為制冷,得電時換向制熱,制冷與制熱信號是由_電腦板控制的。可以將運轉模式定于制熱,并人為將四通閥電磁線圈失電(將線圈電源臨時斷開),由于運轉模式定于制熱,控制器只有在制熱達到設定溫度時才能斷開,低于設定溫度時始終閉合。這樣雖然遙控指令為制熱,但實際動作則為制冷,便可在制冷運行中對室外機進行制冷劑回收操作,操作完成后再恢復四通閥電磁線圈通電。

               

              上一篇:防爆空調懸吊室內機組的安裝

              下一篇:拆卸防爆空調室內外機組

               